Robin SmartPAT 3500

The SmartPAT 3500 performs all of the safety tests required for Class I and Class II appliances. It can be connected to an external serial printer (Robin model SP 1000) via an integral RS 232 Communication Port for automatic downloading and printing of test data.

The SmartPAT 3500 is capable of performing Earth Bond, Insulation and Fuse Continuity Tests. The SmartPAT 3500 has been built to meet the requirements of the IEC publication 1010, Safety Requirements for Electronic Measuring Apparatus.

Robin SmartPAT 3500 Summary

Earth Bond Test 26A,
IT Earth Continuity Test YES -100mA
Insulation Test Voltage 500V
Load Test NO
Earth Leakage Test NO
Touch Current Test NO
Sub Leakage Test NO
Polarity Test NO
Downloadable YES
Memory Size UNKNOWN
Qwerty Keyboard NO
Flash Test NO
110V Load Test NO
Barcode Reader Compatible NO
Direct Printing NO



NOW HAS BUILT IN IEC/EXTENSION LEAD TEST